Rolling Stock Cables | ||||||||||||||||||
|
Integrated 9/11/18/20 Cores 0.75mmsq UIC Databus Cables
FRL-UIC-4G10+2G6+1G2.5+2G0.75
FRL-UIC-4G10+2G6+1G2.5+2G1+2G0.75
FRL-UIC-4Q1S+2G0.75/FRL-UIC-4Q1S+2P0.75S
Application
The cables are used as connecting cables to transmit digital signals inside railway rolling stocks
Construction
For 9 cores UIC databus cables
4 cores: 10 mm2 stranded tinned copper conductor with LSZH insulation..
Combined Element: 3 cores (with Cu-strand 2 x 6mm2, 1 x 2.5mm2) are twisted with a filling element to a
combined element.
Core Wrapping:Overlapped plastic-foil(s).
Elements sheaths:TPE
UIC Data Bus 0.75mm2: Two foam PE or foam skin insulated tinned copper stranded conductors are twisted
together with
two filling elements to a pair.
Core Wrapping:Overlapped plastic-foil(s).
Screen:Tin plated copper braid
Elements sheaths:TPE
Core Wrapping:Overlapped plastic-foil(s).
Stranding: 4 strands are twisted to a core together with 3 cored element, the UIC data bus and two fillers
Core Wrapping:Overlapped plastic-foil(s).
Outer Sheath:Cross-linked oil resistant LSZH compound.
For 11 cores UIC databus cables
4 cores: 10 mm2 stranded tinned copper conductor with LSZH insulation
Combined Element: 5 cores (with Cu-strand 2 x 6mm2, 1 x 2.5mm2 and 2 x 1.0 mm2) are twisted with a filling
element to form a combined element.
Core Wrapping:Overlapped plastic-foil(s).
Element sheaths:TPE
UIC Data Bus 0.75mm2: Two foam PE or foam skin insulated tinned copper r stranded conductors are twisted
together with two filling elements to a pair.
Core Wrapping:Overlapped plastic-foil(s).
Screen:Tin plated copper braid.
Element sheaths:TPE
Core Wrapping:Overlapped plastic-foil(s).
Stranding:4 strands are twisted to a core together with 5 cored element, the UIC data bus and two fillers.
Core Wrapping:Overlapped plastic-foil(s).
Outer Sheath:Cross-linked oil resistant LSZH compound.
For 18/20 cores UIC databus cables
Star Quad: Four LSZH insulated 1mm2 stranded tinned copper conductors are twisted to form a star quad.
UIC Data Bus 0.75mm2: Two foam PE or foam skin insulated tinned copper stranded conductors are twisted
together with two filling elements to form a pair.
Core Wrapping: Overlapped plastic-foil(s).
Screen: Tin plated copper braid
Element sheaths: TPE.
Core Wrapping: Overlapped plastic-foil(s).
Stranding: 4 star quads are stranded together with 2 or 4 UIC data bus cable and several fillers.
Core Wrapping: Overlapped plastic-foil(s).
Screen:Tin plated copper braid.
Outer Sheath:Cross-linked oil resistant LSZH compound.
Electrical & Mechanical Properties
Nominal Voltage:300V
Maximum Conductor Temperature:90℃
Minimum Permissible Ambient Temperature:-40°C
Bending Radius:12 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2:No fluorine
EN 50305; EN 60811-2-1:Resistance to mineral oil & fuel oil, acid & alkali
EN 50305:Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2:Hazard levels HL1, HL2/HL3
DIN 5510-2:Protection level 1/2/3/4
BS 6853:Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101:FO
EN45545-2:R15 Interior/ R16 Exterior HL1, HL2, HL3
Fire Performance in general
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 |
Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 |
Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 | Low Toxicity |
NFF 16101; NFF 63808; BS6853 | Smoke index |
EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
FRL-UIC-4G10+2G6+1G2.5+2G0.75
Nominal Cross Sectional Area |
Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Maximum Conductor Resistance | Impedance | Maximum Attenuation | |||
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm2 | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.8 | 25 | 917 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
10 | 80/0.4 | 1.95 | - | - | - | - | - | |||
6 | 84/0.3 | 3.39 | - | - | - | - | - | |||
2.5 | 37/0.29 | 8.21 | - | - | - | - | - |
FRL-UIC-4G10+2G6+1G2.5+2G1+2G0.75
Nominal Cross Sectional Area |
Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Maximum Conductor Resistance | Impedance | Maximum Attenuation | |||
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm2 | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.8 | 25 | 969 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
10 | 80/0.4 | 1.95 | - | - | - | - | - | |||
6 | 84/0.3 | 3.39 | - | - | - | - | - | |||
2.5 | 37/0.29 | 8.21 | - | - | - | - | - |
FRL-UIC-4Q1S+2G0.75
Nominal Cross Sectional Area |
Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Maximum Conductor Resistance | Impedance | Maximum Attenuation | |||
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm2 | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.8 | 18.5 | 498 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
1 | 19/0.25 | 20 | - | - | - | - | - |
FRL-UIC-4Q1S+2P0.75S
Nominal Cross Sectional Area |
Number & Nominal Diameter of Strands | Nominal Sheath Thickness | Nominal Overall Diameter | Nominal Weight | Maximum Conductor Resistance | Impedance | Maximum Attenuation | |||
20°C | @0.75-3MHz | @1MHz | @1.5MHz | @2MHz | @3MHz | |||||
mm2 | No/mm | mm | mm | kg/km | Ω/km | Ω | dB/km | dB/km | dB/km | dB/km |
0.75 | 19/0.22 | 1.5 | 23 | 530 | 26.7 | 120+/-12 | 10 | 13 | 14 | 18 |
1 | 19/0.25 | 20 | - | - | - | - | - |